Extremely fast response time; class 1; measuring ranges from -200°C up to +800°C
Mounting types and metrological properties as Fig. 380; Fig. 381; Fig. 382; Fig. 383
Remote measurement within a maximum distance of 50 m, works without external energy supply and, therefore, also in the event of power failures
For direct temperature indication at the measuring point and simultaneous system controlling (electrical output signal, proportional to measured temperature)
The switching point can be adjusted within the entire measuring range (280°) in the centre of the viewing glass. The contacts switch, as soon as the temperature has reached the set limit.
Energy supply required
The breaking capacity depends on the circuit amplifier used. The non-contact proximity switches in the measuring device switch the circuit amplifier with the auxiliary energy of the energy supply.
Can be used with glycerine filling or other damping fluids
Works without energy supply and, therefore, also in the event of power failures