Space saving remote reading thermometer in profile design and drum scale
For horizontal flush mounting, with triangular front ring and lateral snap catches
Without external energy supply, for the measurement of the two standard measuring ranges -40°C/+40°C and 0°C/120°C, with a maximum distance of 10m from the indicating device
Without temperature compensation, i.e. the measurement result is influenced by temperature changes on the measuring line
technical features:
Measuring principle: Temperature-dependent volume expansion of anorganic fluids
Scale ranges: 0°C/120°C; -40°C/+40°C
Measuring accuracy: +/- 3% of end scale value
Connection position: on the backside
Housing material: ABS, black or white, resistant up to +80°C
housing protection type: IP41 acc. to EN 60529/IEC 529
Pointer correcting adjustment: Adjusting screw
limits of use: max. 6 bar on plain measuring stem, without thermowell
Standard measuring stem: Smooth sensor, diameter 3.3 mm