Specially designed for the use in food industry and hygienic applications
Cleaning and sterilisation possible in cyclic and continuous processes (CIP and SIP); maximum cleaning temperature of 150°C
Dead-leg-free, the diaphragm is front flush welded
For the protection of pressure measuring devices from excessively hot or aggressive measuring media
For remote measurements without external energy supply, a remote sensor can be installed between chemical seal and indicating device within a maximum distance of 5 m. Differences in altitude between the chemical seal and the indicating device must be taken into account in the construction of the measurement system.
The factory-mounted, adjusted and calibrated measurement system comprises the chemical seal and - depending on the customer request - a pressure gauge, pressure measuring transducer or other pressure measuring devices
technical features:
Measuring device connection: G1/2B, female thread
Process connection: acc. to ISO 2852 with clamp connection
Diaphragm: CrNi steel 1.4435, front flush welded, dead-leg-free
Limits of use: - Maximum nominal pressure: 25 bar or 40 bar, depending on the nominal width, see dimension table - Minimum reading range (pressure gauge NS 100), see dimension table