Protection from hot measuring media and pulsating pressure fluctuations (acc. to EN 837-1, the measuring medium temperature should not exceed 60°C)
Mounting is either made directly before the connection pin of the measuring device or - even better - before the pressure gauge shut-off device (cock or valve)
Before start-up, the siphon is to be filled with cold medium as sealing fluid between pressure and measuring device connection. With gaseous measuring media, a cold condensate is used as cooling section
Measuring device connection with adjusting nut
Pressure tapping point with welding connection
Limits of application: max. 160 bar at max. 120°C or max. 130 bar at max. 400°C
Steel and stainless steel design
technical features:
Product design standard: DIN 16282 Form B
Pressure tapping: in horizontal direction, U-shaped