| Display ranges | -40°C to +380°C |
| Display accuracy | +/- 3% of full scale value |
| Nominal sizes (NG) | 52 mm, 60 mm, 80 mm, 100 mm |
| Connection | with sensor type 00, smooth; Ø 8.5 mm and knurled nut M10x1 with compression spring |
| Material | Housing (sheet steel, galvanized): with chrome-plated triangular front ring or chrome-plated rolling ring for nominal size 100 mm Window: scratch-resistant instrument glass Pointer; black Dial: aluminium, pure white coating, printed in black |
| Enclosure Protection class | IP44 according to EN 60529/IEC 529 |
| Measuring line | Capillary tube made of copper, up to 160°C with plastic sheath, from 160°C with copper sheath |
| Measuring cable length | max. 10 m |

| Nominal size | D | d | b | s | L1 |
|---|---|---|---|---|---|
| 52 | 8,5 | 15 | |||
| 60 | 64 | 8,5 | 24 | 4 | 15 |
| 80 | 84 | 8,5 | 26,5 | 5 | 15 |
| 100 | 8,5 | 15 |
| Customized imprint (text, logo), special scale | on request |
| Thermowell type | Material |
|---|---|
| Protection tube for screwing in (option) | Copper alloy 2.0321 |
Other special versions on request.
Please observe the relevant standards and laws, as well as the installation and operating instructions for thermometers.
In particular, we would like to draw your attention to the suitable measuring materials with regard to material resistance and their maximum measuring material temperature.
This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.