Design standard | JAKO factory standard |
Installation | for screwing in |
Nominal length | One-piece turned: 45 mm, 63 mm Multi-piece brazed: 80 mm to 500 mm |
Minimum immersion depth | 40 mm |
Operating temperature | ≤250 °C |
Material | One-piece turned: copper alloy 2.0321 Multi-piece brazed Tube: copper alloy 2.0321 Nipple: copper alloy 2.0321 Locking screw: M3 VA |
Flow velocity | <1.5 m/s |
Nominal pressure PN | 6 bar |
Material resistance | see material resistance list |
Ambient and storage temperature | -20°C to +60°C |
Shape | D1 | D2 | B1 | S | B2 | SW | U1 |
01, soldered | 9 | – | 7,2 | – | 7 | 22 | 80-500 |
01, solid material | 9 | – | 7,2 | 3 | 7 | 22 | 39,5/57,5 |
All dimensions in millimeters.
all nominal lengths | M14x1.5 CrNi steel 1.4571 |
all nominal lengths | M18x1.5 CrNi steel 1.4571 |
all nominal lengths | G1/2 CrNi steel 1.4571 |
all nominal lengths | G3/4 CrNi steel 1.4571 |
Please note the General information on temperature measuring devices.
The load specifications are based in part on highly simplified assumptions for the mechanical stresses occurring in the protective conduits under idealized operating conditions. For example, pulsating incident flows are not taken into account. The data can therefore only be of an indicative nature for thermowells under real operating conditions. They do not provide complete security against breakage or tearing.
This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.
Contact us and we will advise you comprehensively on possible solutions!