Design standard | Factory standard |
Measuring principle | Elastic measuring elements (Bourdon tube), which deform under pressure Dial thermometer, which is operated by the different expansion of helically arranged bimetallic strips |
Nominal size | 80 mm |
Display ranges | 0-4 bar / 0-120°C and 0-6 bar / 0-120°C |
Scale | Temperature scale (red), pressure scale (blue) |
Accuracy class | Pressure: 2.5 Temperature: 2 |
Load capacity | Resting pressure load: 75% of full scale value, overload full scale value Dynamic load: 30% to 60% of full scale value, up to 30,000 load cycles |
Connection position | Free-standing process connection: -bottom |
Material | Housing: Steel Cover ring: Chrome-plated steel Window: Plexiglas Measuring element: Copper alloy Pressure connection pin and temperature sensor: Copper alloy Pointer: Aluminium, black anodized Dial: Aluminium, white coated, black printed Brand pointer: Plastic |
Enclosure protection class | IP32 according to EN 60529 |
Pointer stop | Pressure: with stop pin (zero point) |
Medium temperature | 0 °C to +120 °C |
Ambient and storage temperature | -20 °C to +60 °C |
Suitable media | Media in heating circuits that do not attack the copper alloy |
Red brand pointer | adjustable from the outside |
Nominal size | D | b | c | h | SW | SW1 |
80 | 80 | 29,5 | 61,5 | 15 | 21 | 14 |
All dimensions in millimeters.
Special scale for standard measuring range | from 100 pcs. |
Other special versions on request.
Automatic valve protective sleeve | G1/2 B, copper alloy |
Other special versions on request.
Please observe the relevant standards and laws, as well as the installation and operating instructions for pressure gauges and installation and operating instructions for thermometers.
Can only be used in conjunction with the automatic valve protection sleeve G1/2 B.
In particular, we would like to draw your attention to the suitable media with regard to material resistance and their maximum media temperature.
This device type is only designed for use in weather-protected indoor areas and is not suitable for operating conditions with vibrations and shocks.
This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.