Design standard | based on EN 837-1 |
Measuring principle | Elastic measuring elements (Bourdon tube) that deform under pressure load |
Nominal size | 63 mm, 80 mm |
Display range | 0 bar to 4 bar |
Accuracy class | 1,6 |
Load capacity | Resting pressure load: 75% of full scale value, overload full scale value Dynamic load: 30% to 60% of full scale value, up to 30,000 load cycles |
Installation types and position of the pressure connection spigots | Free-standing process connection: -bottom -rear centric |
Material | Housing: Sheet steel, painted black Cover ring: Nominal size 80 mm chrome-plated steel Window: Plexiglas Measuring element: Copper alloy Pressure connection pin: Copper alloy Pointer: Aluminium, black anodized Dial: Nominal size 63 mm plastic, nominal size 80 mm aluminium, white, black printed |
Enclosure protection class | IP32 according to EN 60529 |
Pointer stop | with stop pin (zero point) |
Medium temperature | 0°C to 100°C |
Ambient and storage temperature | -20°C to +60°C |
Suitable media | Media in heating circuits that do not attack the copper alloy |
Red brand pointer | adjustable from the outside |
Nominal size | D | b | c | c1 | h | e | SW |
63 | 62 | 30 | 54 | 49 | 13 | 10 | 14 |
80 | 81 | 32 | 69 | 32,5 | 20 | 11,5 | 14 |
All dimensions in millimeters.
Customized imprint (text, logo) on standard scale | from 100 pcs. |
Special threads (e.g. NPT, BSP, metric) | from 100 pcs. |
Throttle screw | from 100 pcs. |
Impact protection cap | from 1 pc. |
Other special versions on request.
Nominal size 63 | G1/4 B or G3/8 B, copper alloy |
Nominal size 80 | G1/4 B or G1/2 B, copper alloy |
Other special versions on request.
Please observe the relevant standards and laws, as well as the installation and operating instructions for pressure gauges.
In particular, we would like to draw your attention to the suitable media with regard to material resistance and their maximum media temperature.
This device type is only designed for use in weather-protected indoor areas and is not suitable for operating conditions with vibrations and shocks.
This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.
Contact us and we will advise you comprehensively on possible solutions!