Inductive contact Fig. 18.20

Symbol image

Inductive contact Fig. 18.20

Application and performance features of the inductive contact
  • Limit value switches with inductive contacts can only be used in combination with switching amplifiers and can supply up to 4 independent switching signals simultaneously. The switching amplifier supplies the switching signal as a binary output signal.

  • Possible switching states: normally open or normally closed contact

  • The switching points are set using red limit value pointers via an adjustment lock in the center of the instrument glass.

  • Inductive contacts must be supplied with power externally

  • Inductive contacts have a long service life as the switching process is contactless.

  • Precise switching point: 0.5% of the full scale value.

  • Suitable for industrial use, especially for vibration-damped oil-filled dial gauges

  • Approved for use in hazardous explosive atmospheres (ATEX type examination)

Technical data – General

Standard

EN 60947-5-6

Nominal voltage

8V (DC)

Operating voltage

5 – 25V

Power consumption in idle state

≥ 3mA

Current consumption in switching state when setpoint pointer and actual value pointer are congruent and the control lug comes to rest in the air gap of the slotted initiator

≤ 1mA

Switching accuracy in % of full scale value

0,5%

Contact setting range in scale angular degrees

280°

Technical data – Standard slot initiator

Slotted initiator type for NG 63, NG 100

SJ 2 N (green) Pepperl+Fuchs

Slot initiator type for NG 160, only if SJ 2 N is not used for height reasons

SJ 3.5 N (green) Pepperl+Fuchs

Ambient temperature

-20°C to +70°C

Application limits according to EC type examination certificate

PTB 99 ATEX 2219 X

Labeling of the device

Ex II 2 G EEx ia IIC T6

Technical data – Safety slot initiator (optional)

Slotted initiator type for NG 63, NG 100

SJ 2 SN, SJ 2 S1N (green) Pepperl+Fuchs

Slot initiator type for NG 160, only if SJ 2 N is not used for height reasons

SJ 3.5 SN, SJ 3.5 S1N (green) Pepperl+Fuchs

Ambient temperature

-20°C to +70°C

Application limits according to EC type examination certificate

PTB 00 ATEX 2049 X

Labeling of the device

Ex II 2 G EEx ia IIC T6

Technical data

Setting range

280 angular degrees

Switching accuracy

0.5% of the full scale value

Number of limit switch contact assemblies

NG 63: up to 2 contacts
NG100, NG160: up to 4 contacts

Electrical connection

Cable junction box, lateral, blue

Max. Cable cross-section

1.5 mm²

Protection class of the junction box

PG cable gland, IP65 in accordance with EN 60529

Applicable regulations for use and connection

EN 60947-5-6 (NAMUR)

EC type examination certificate in accordance with ATEX

EN 500014:1997

EN 50020;1994

Contact variants and switching function in accordance with DIN 16085, DIN 16196

Type designation

Switching behavior at the clockwise switching point

I1

Contact closes

I2

Contact opens

I3

Single changeover contact

I11

  1. Contact closes

  2. Contact closes

I12

  1. Contact closes

  2. Contact opens

I21

  1. Contact opens

  2. Contact closes

I22

  1. Contact opens

  2. Contact opens

> 3 Contacts

see connection diagrams/on request

 

Connection diagrams, type designation, of the junction box for devices with up to 3 contacts

Connection options

Options

3 separate circuits

2 separate circuits

2nd circuit disconnected

3rd circuit disconnected

Additional adjustment key

This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.

Accessories
No accessories found for this product
Alternative products
No alternatives found for this product
Are you looking for a special product or do you need an individual offer?

Contact us and we will advise you comprehensively on possible solutions!