Shut-off and throttling device for direct installation upstream of the pressure gauge, either after the cooling section, e.g. siphon or directly at the pressure tapping point of the pressure line: Siphon or directly at the pressure tapping point of the pressure line;
Test connection for a test pressure gauge to check the function of an operating pressure gauge on the same pressure line during operation.
Shaft for measuring device holder
Venting screw for pressure relief when shut off
Pressure tapping side with spigot G1/2B and pressure gauge connection with rotatable socket G1/2B;
Highly corrosion and chemical resistant in stainless steel design
Max. Operating pressure up to 400 bar in stainless steel design
Highly temperature-resistant, from -20°C to +200°C in stainless steel design
The test connection is shut off during normal operation by means of a screw plug and sealing ring
This specification refers to our current standard with regard to design, dimensions and materials. JAKO Messtechnik GmbH reserves the right to make changes or modifications without prior notice.